Ограничение резонансных токов при испытаниях электроприводов постоянного тока в системе генератор–двигатель

Ескіз

Дата

2010

ORCID

DOI

item.page.thesis.degree.name

item.page.thesis.degree.level

item.page.thesis.degree.discipline

item.page.thesis.degree.department

item.page.thesis.degree.grantor

item.page.thesis.degree.advisor

item.page.thesis.degree.committeeMember

Назва журналу

Номер ISSN

Назва тому

Видавець

НТУ "ХПИ"

Анотація

The Possibility of the resonance currents limitation in the loading system on the basis of direct-current is shown. The generator works in the self-oscillating mode by introduction of additional resistance in the parallel excitation winding of the generator. The effective current - frequency of resistance commutation dependence was resulted during mathematical modeling. The questions of additional resistance commutation are considered taking into account a change of the time constant of the parallel excitation winding of the generator.

Опис

Ключові слова

машина электрическая, нагружение динамическое, режим автоколебательный, возбуждение смешанное, частота коммутации

Бібліографічний опис

Коваль В. А. Ограничение резонансных токов при испытаниях электроприводов постоянного тока в системе генератор–двигатель / В. А. Коваль, С. А. Сергиенко // Вестник Нац. техн. ун-та "ХПИ" : сб. науч. тр. Темат. вып. : Проблемы автоматизированного электропривода. Теория и практика. – Харьков : НТУ "ХПИ", 2010. – № 28. – С. 484-486.