Please use this identifier to cite or link to this item: http://repository.kpi.kharkov.ua/handle/KhPI-Press/26382
Title: Влияние типа и размера расчетных сеток на точность расчета течений в вихрекамерных нагнетателях
Other Titles: Influence of grids type and size on accuracy of fluid flow computation in vortex chamber superchargers
Authors: Сёмин, Дмитрий Александрович
Роговой, Андрей Сергеевич
Keywords: погрешность расчета; верификация; интегральные параметры; расчетная сетка; calculation error; verification; integrated parameters
Issue Date: 2016
Publisher: НТУ "ХПИ"
Citation: Сёмин Д. А. Влияние типа и размера расчетных сеток на точность расчета течений в вихрекамерных нагнетателях / Д. А. Сёмин, А. С. Роговой // Вісник Нац. техн. ун-ту "ХПІ" : зб. наук. пр. Темат. вип. : Гідравлічні машини та гідроагрегати = Bulletin of National Technical University "KhPI" : coll. of sci. papers. Ser. : Hydraulic machines and hydrounits. – Харків : НТУ "ХПІ", 2016. – № 41 (1213). – С. 70-77.
Abstract: На основе численного расчета течений в вихрекамерном нагнетателе с помощью моделей URANS и DES произведено исследование влияния типа и размера расчетных сеток на точность расчета. Получено, что погрешность расчета перестает меняться при числе элементов более 6 млн. Для модели DES это значение больше в два раза. При использовании детальной сетки целесообразней использовать тетрагональную сетку.
On the basis of numerical calculation of fluid flow in vortex chamber supercharger by means of models URANS and DES research of grids type and size influence on accuracy of computation is made. It is received that the calculation error ceases to change at number of elements more than 6 million For DES method this value in 2 times is more. At flow modelling in vortex chamber supercharger with a detailed grid, owing to more difficult construction hexagonal grids, it is more expedient to use a tetragonal grid in the absence of special distinctions in an error. The estimation of errors is made by comparison with the integrated parameters of a flows received experimentally. As a result of comparison on kinematics parameters, such as distribution of pressure to a end cover of the vortex chamber is received that all considered models give about an identical error.
URI: http://repository.kpi.kharkov.ua/handle/KhPI-Press/26382
Appears in Collections:Вісник № 41

Files in This Item:
File Description SizeFormat 
vestnik_KhPI_2016_41_Semin_Vliyanie.pdf5,04 MBAdobe PDFThumbnail
View/Open
Show full item record  Google Scholar



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.