Title: Влияние жёсткости элементов водяной камеры конденсатора паровой турбины на отклик от динамического воздействия
Other Titles: The influence produced by the stiffening members of the water chamber of the steam turbine condenser on the dynamic action response
Authors: Воробьев, Юрий Сергеевич
Солохин, М. А.
Губский, А. Н.
Keywords: стяжки; напряжения; напряжённо-деформированное состояние; water chamber; tie; stresses; mode of deformation; dynamic action
Issue Date: 2014
Publisher: НТУ "ХПИ"
Citation: Воробьев Ю. С. Влияние жёсткости элементов водяной камеры конденсатора паровой турбины на отклик от динамического воздействия / Ю. С. Воробьев, М. А. Солохин, А. Н. Губский // Вестник Нац. техн. ун-та "ХПИ" : сб. науч. тр. Темат. вып. : Энергетические и теплотехнические процессы и оборудование. – Харьков : НТУ "ХПИ". – 2014. – № 13 (1056). – С. 147-155.
Abstract: Рассчитано напряжённо-деформированное состояние (НДС) в водяной камере конденсатора паровой турбины большой мощности при динамическом воздействии. Проведена оценка работоспособности водяной камеры конкретной конструкции после варьирования жёсткостью её элементов. Получена формула для плоских стенок, укреплённых стяжками, отражающая зависимость между НДС в стяжках и геометрией конструкции. Для проверки универсальности данной зависимости были проведены тестовые расчёты.
The mode of deformation in the water chamber of the steam turbine condenser of a high power was calculated for dynamic action. The operability of the water chamber of a specific structure after varying the rigidness of its elements has been estimated. A formula for flat walls reinforced with ties, which shows the relationship between the mode of deformation in the ties and the structure geometry has been derived. Test computations were done to verify the universality of this relationship. Test computations confirmed the validity of statements done in the paper with regard to the universality of the formula obtained for flat wall structures reinforced with the ties of circular cross section at a known value of dynamic pressure. The conclusion was made that some K value that depends on geometric characteristics of the structure can be calculated for the structure with flat walls reinforced with the ties of circular cross section, for example, the water chambers of steam turbine condensers. The structure response to the dynamic action will depend on this value.
URI: http://repository.kpi.kharkov.ua/handle/KhPI-Press/8934
Appears in Collections:Вісник № 13

Files in This Item:
File Description SizeFormat 
vestnik_HPI_2014_13_Vorobyev_Vliyaniye.pdf4,61 MBAdobe PDFThumbnail
View/Open
Show full item record  Google Scholar



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.