Total Site Integration for Coke Oven Plant

dc.contributor.authorUlyev, L. M.en
dc.contributor.authorKapustenko, P. O.en
dc.contributor.authorVasilyev, M. A.en
dc.contributor.authorBoldyryev, S. A.en
dc.date.accessioned2017-03-09T10:34:20Z
dc.date.available2017-03-09T10:34:20Z
dc.date.issued2013
dc.description.abstractThe process of benzene distillation and process of coal tar distillation being typical for East European countries is analyzed in this paper. The pinch analysis method was selected to perform a reconstruction project. According to principles of pinch analysis, new network diagrams are designed and capacity of heatexchange equipment is calculated. The using of "Total Site Profiles" showed the feasibility of heat pump integration. Heat pump integration allowed to reduce the external hot utilities usage on 368 kW and cold utilities usage on 368 kW. This project let to decrease the external hot utilities usage on 23 % and cold utilities usage on 24,13 %, and also offered the way of step-by-step retrofit of the plant.en
dc.identifier.citationTotal Site Integration for Coke Oven Plant / L. M. Ulyev [et al.] // Chemical Engineering Transactions. – 2013. – Vol. 35. – P. 235-240.en
dc.identifier.doi10.3303/CET1335039
dc.identifier.urihttps://repository.kpi.kharkov.ua/handle/KhPI-Press/27653
dc.language.isoen
dc.publisherThe Italian Association of Chemical Engineeringen
dc.titleTotal Site Integration for Coke Oven Planten
dc.typeArticleen

Файли

Контейнер файлів
Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
2013_Ulyev_Total_Site_Integration.pdf
Розмір:
986.59 KB
Формат:
Adobe Portable Document Format
Ліцензійна угода
Зараз показуємо 1 - 1 з 1
Ескіз недоступний
Назва:
license.txt
Розмір:
11.23 KB
Формат:
Item-specific license agreed upon to submission
Опис: