(НТУ "ХПИ", 2010) Гребченко, Николай Васильевич; Сидоренко, Алексей Анатольевич
A method of electric motors diagnosing in operating condition (without switching off electric motors) is considered. The method allows identifying the main types of defects in stator winding insulation and mechanical damage to the unit. In the method as input information used parameters of the current mode of accession.