Видання НТУ "ХПІ"

Постійне посилання на розділhttps://repository.kpi.kharkov.ua/handle/KhPI-Press/62886

Переглянути

Результати пошуку

Зараз показуємо 1 - 7 з 7
  • Ескіз
    Документ
    Optimization of spatial arrangement of magnetic field sensors of closed loop system of overhead power lines magnetic field active silencing
    (Національний технічний університет "Харківський політехнічний інститут", 2023) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.
    Development of a method for optimization of spatial arrangement and angular position of magnetic field sensors of a closed system to ensure maximum efficiency of active silencing canceling of the magnetic field generated by overhead power lines. Methodology. Spatial arrangement and angular position of magnetic field sensors of closed loop system of overhead power lines magnetic field active silencing determined based on binary preference relations of local objective for multi-objective minimax optimization problem, in whith the vector objective function calculated based on Biot–Savart law. The solution of this vector minimax optimization problem calculated based on nonlinear Archimedes algorithm of multi-swarm multi-agent optimization. Results. Results of simulation and experimental research of optimal spatial arrangement and angular position of magnetic field sensors of a closed system to ensure maximum efficiency of active silencing of the magnetic field generated by overhead power lines with a barrel-type arrangement of wires. Originality. The method for optimization of spatial arrangement and angular position of magnetic field sensors of a closed system to ensure maximum efficiency of active shielding of the magnetic field generated by overhead power lines is developed. Practical value. An important practical problem optimization of spatial arrangement and angular position of magnetic field sensors of a closed system to ensure maximum efficiency of active silencing of the magnetic field generated by overhead power lines has been solved.
  • Ескіз
    Документ
    The method of multi-objective parametric design of magnetic field active canceling robust system for residential multy-story buildings closed to double-circuit overhead power lines
    (Національний технічний університет "Харківський політехнічний інститут", 2023) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.
    Aim. Development the method of multi-objective parametric design for robust system of active canceling of magnetic field based on binary preference relations of local objective for multi-objective minimax optimization problem. Methodology. Spatial location coordinates of the compensating winding and the current in the shielding winding were determined during the preference-based multi-objective parametric design of systems of active canceling based on solution of the vector minimax optimization, in whith the vector objective function calculated based on Biot-Savart's law. The solution of this vector minimax optimization problem calculated based on nonlinear Archimedes algorithm. Components of Jacobi matrix and Hesse matrix calculated based on multi-swarm multi-agent optimization. Results. Theoretically and experimentally confirmed the effectiveness of reducing the level of the magnetic field in residential multy-storey old building of a doublecircuit overhead power transmission lines with a barrel-type arrangement of wires by means of active shielding with two compensation winding. Originality. The method of multi-objective parametric design for robust system of active canceling of magnetic field based on binary preference relations of local objective for multi-objective minimax optimization problem is developed. Practical value. It is shown the possibility to reduce the level of magnetic field in residential multy-storey old building closed to double-circuit overhead power transmission lines with a barrel-type arrangement of wires by means of system of active canceling with two canceling winding to a level safe for the population with an induction of 0.5 μT.
  • Ескіз
    Документ
    Synthesis of an effective system of active shielding of the magnetic field of a power transmission line with a horizontal arrangement of wires using a single compensation winding
    (Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.
    Aim. The theoretical and experimental studies of the effectiveness of reducing the level of the magnetic field in two-storey cottage of the old building of a power transmission line with a horizontal arrangement of wires by means of active shielding with single compensation winding. Methodology Spatial location coordinates of the compensating winding and the current in the shielding winding were determined during the design of systems of active screening based on solution of the vector game, in whith the vector payoffs is calculated based on Biot-Savart's law. The solution of this vector game calculated based on algorithms of multi-swarm multi-agent optimization. Results The results of theoretical and experimental studies of the effectiveness of reducing the level of the magnetic field in two-storey cottage of the old building of a power transmission line with a horizontal arrangement of wires by means of active shielding with single compensation winding are presented. Originality. For the first time, the theoretical and experimental studies of the effectiveness of reducing the level of the magnetic field in two-storey cottage of the old building of a power transmission line with a horizontal arrangement of wires by means of active shielding with single compensation winding are considered. Practical value. From the point of view of the practical implementation it is shown the possibility to reduce the level of magnetic field in two-storey cottage of the old building from power transmission line with a horizontal arrangement of wires by means of active shielding with single compensation winding to the sanitary standards of Ukraine.
  • Ескіз
    Документ
    The method of multi objective synthesis of stochastic robust control by multimass electromechanical systems under non-gausian random external disturbances
    (Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.
    Development of the method of multi objective synthesis of stochastic robust control by multimass electromechanical systems to satisfy various requirements for the operation of such systems in various modes under non-gausian random external disturbances. Methodology. The problem of multi objective synthesis of stochastic robust control by multimass electromechanical systems to satisfy various requirements for the operation of such systems in various modes under non-gausian random external disturbances solved based on the choosing of weight matrices in the robust control goal vector.The calculation of the target vector is performed based on the solution of the zero-sum vector antagonistic game. The components of the game payoff vector are variable quality indicators that are applied to the system operation in various modes. The calculation of the components of payoff vector game are performed based on the simulation of the initial system closed by the synthesized stochastic controllers in various operating modes and under various external influences and variations in the parameters of the uncertainty of the initial plant. Results. The results of multi objective synthesis of stochastic robust twomass electromechanical servo systems modes under non-gausian random external disturbances in which differences requirements for the operation of such systems in various modes were satisfied are given. Based on the results of modeling and experimental studies it is established, that with the help of synthesized robust nonlinear controllers, it is possible to improve of quality indicators of two-mass electromechanical servo system in comparison with the system with standard regulators. Originality. For the first time the method of multi objective synthesis of stochastic robust control by multimass electromechanical systems to satisfy various requirements for the operation of multimass systems in various modes is developed. Practical value. From the point of view of the practical implementation the possibility of solving the problem of multi objective synthesis of stochastic robust control systems to satisfy various requirements for the operation of multimass electromechanical systems in various modes is shown.
  • Ескіз
    Документ
    The method of multi objective synthesis of nonlinear robust control by multimass electromechanical systems
    (Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobilyanskiy, B. B.
    Development of the method of multi objective synthesis of nonlinear robust control by multimass electromechanical systems to satisfy various requirements for the operation of multi-mass systems in various modes. Methodology. The problem of multi objective synthesis of nonlinear robust control of multimass electromechanical systems is formulated and the possibility of satisfying various requirements for the operation of such systems in various modes based on the concept of functionally multiple membership of the state vector and the solution of the Hamilton-Jacobi-Isaacs equation is shown. A method for choosing weight matrices with the help the vector of purpose of nonlinear robust control is formed by solving a zero-sum vector antagonistic game has been substantiated and developed. Results. The results multi objective synthesis of nonlinear robust two-mass electromechanical servo systems in which differences requirements for the operation of such systems in various modes were satisfied are given. Based on the results of modeling and experimental studies it is established, that with the help of synthesized robust nonlinear controllers, it is possible to improve of quality indicators of two-mass electromechanical servo system in comparison with the system with standard regulators. Originality. For the first time the method of multi objective synthesis of nonlinear robust control by multimass electromechanical systems to satisfy various requirements for the operation of multimass systems in various modes is developed. Practical value. From the point of view of the practical implementation the possibility of solving the problem of multi objective synthesis of nonlinear robust control systems to satisfy various requirements for the operation of multimass electromechanical systems in various modes is shown.
  • Ескіз
    Документ
    Comparison of the effectiveness of thriple-loop and double-loop systems of active shielding of a magnetic field in a multi-storey old buildings
    (Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.
    The issues of comparing the effectiveness of reducing the level of the magnetic field in a five-storey old buildings generated by a single-circuit overhead power transmission lines with a triangular suspension of wires using a thriple-loop and double-loop systems of active screening, which respectively contain three or two compensating windings are considered. Methodology. Spatial location coordinates of the compensating windings and the currents in the shielding windings were determined during the design of systems of active screening based on solution of the maximin vector optimization problem, in whith the vector of objective function is calculated based on Biot-Savart's law. The solution of this problem is calculated based on algorithms of multi-swarm multi-agent optimization. Results. The results of theoretical and experimental comparing the effectiveness of reducing the level of the magnetic field in a five-storey old generated by a single-circuit overhead power transmission lines with a triangular suspension of wires using a thriple-loop and double-loop systems of active screening, which respectively contain three or two compensating windings are presented. Originality. For the first time, the comparison the effectiveness of reducing the level of the magnetic field in a five-storey old using a thriple-loop and double-loop systems of active screening are considered. Practical value. From the point of view of the practical implementation it is shown the possibility to reduce the level of magnetic field induction in a five-storey old buildings to the sanitary standards of Ukraine for real overhead power transmission lines currents with the help of a synthesized double-loop systems of active screening. A double-loop active screening system is simpler in comparison with a thriple-loop active screening system when implementing.
  • Ескіз
    Документ
    Method of adjustment of three circuit system of active shielding of magnetic field in multi-storey buildings from overhead power lines with wires triangular arrangement
    (Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskiy, B. B.
    For the first time the method of adjustment of three circuit system of the active shielding of the magnetic field based on experimentally determined space-time characteristics to increase the shielding factor in a multi-storey building located near a singlecircuit overhead transmission lines with a wires triangular arrangement was developed. Methodology. When synthesizing the laboratory model of system of active shielding the coordinates of spatial arrangement and of three shielding coils, the currents in shielding coils and resulting magnetic flux density value in the shielding space were calculated. The synthesis is based on the multi-criteria game decision, in which the payoff vector is calculated on the basis on quasi-stationary approximation solutions of the Maxwell equations. The game decision is calculated based on the stochastic particles multi swarm optimization algorithms. Results. Computer simulation and experimental research of the space-time characteristics of laboratory model of three circuit system of active shielding of magnetic field, generated by overhead power lines with phase conductors triangle arrangements in multi-storey building are given. The possibility of initial magnetic flux density level reducing to the sanitary standards level is shown. Originality. For the first time the synthesis and adjustment of laboratory model of three circuit system of active shielding of magnetic field based on experimentally determined spacetime characteristics to increase the shielding factor in a multi-storey building located near a single-circuit overhead transmission lines with a wires triangular arrangement carried out. Practical value. Practical recommendations from the point of view of the implementation of developed method of adjustment of the three circuit system of the active shielding of the magnetic field based on experimentally determined space-time characteristics in a multi-storey building located near a single-circuit overhead transmission lines with a triangular arrangement of wires are given.