Видання НТУ "ХПІ"
Постійне посилання на розділhttps://repository.kpi.kharkov.ua/handle/KhPI-Press/62886
Переглянути
4 результатів
Результати пошуку
Документ Optimization of spatial arrangement of magnetic field sensors of closed loop system of overhead power lines magnetic field active silencing(Національний технічний університет "Харківський політехнічний інститут", 2023) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.Development of a method for optimization of spatial arrangement and angular position of magnetic field sensors of a closed system to ensure maximum efficiency of active silencing canceling of the magnetic field generated by overhead power lines. Methodology. Spatial arrangement and angular position of magnetic field sensors of closed loop system of overhead power lines magnetic field active silencing determined based on binary preference relations of local objective for multi-objective minimax optimization problem, in whith the vector objective function calculated based on Biot–Savart law. The solution of this vector minimax optimization problem calculated based on nonlinear Archimedes algorithm of multi-swarm multi-agent optimization. Results. Results of simulation and experimental research of optimal spatial arrangement and angular position of magnetic field sensors of a closed system to ensure maximum efficiency of active silencing of the magnetic field generated by overhead power lines with a barrel-type arrangement of wires. Originality. The method for optimization of spatial arrangement and angular position of magnetic field sensors of a closed system to ensure maximum efficiency of active shielding of the magnetic field generated by overhead power lines is developed. Practical value. An important practical problem optimization of spatial arrangement and angular position of magnetic field sensors of a closed system to ensure maximum efficiency of active silencing of the magnetic field generated by overhead power lines has been solved.Документ The method of multi-objective parametric design of magnetic field active canceling robust system for residential multy-story buildings closed to double-circuit overhead power lines(Національний технічний університет "Харківський політехнічний інститут", 2023) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.Aim. Development the method of multi-objective parametric design for robust system of active canceling of magnetic field based on binary preference relations of local objective for multi-objective minimax optimization problem. Methodology. Spatial location coordinates of the compensating winding and the current in the shielding winding were determined during the preference-based multi-objective parametric design of systems of active canceling based on solution of the vector minimax optimization, in whith the vector objective function calculated based on Biot-Savart's law. The solution of this vector minimax optimization problem calculated based on nonlinear Archimedes algorithm. Components of Jacobi matrix and Hesse matrix calculated based on multi-swarm multi-agent optimization. Results. Theoretically and experimentally confirmed the effectiveness of reducing the level of the magnetic field in residential multy-storey old building of a doublecircuit overhead power transmission lines with a barrel-type arrangement of wires by means of active shielding with two compensation winding. Originality. The method of multi-objective parametric design for robust system of active canceling of magnetic field based on binary preference relations of local objective for multi-objective minimax optimization problem is developed. Practical value. It is shown the possibility to reduce the level of magnetic field in residential multy-storey old building closed to double-circuit overhead power transmission lines with a barrel-type arrangement of wires by means of system of active canceling with two canceling winding to a level safe for the population with an induction of 0.5 μT.Документ Synthesis of an effective system of active shielding of the magnetic field of a power transmission line with a horizontal arrangement of wires using a single compensation winding(Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.Aim. The theoretical and experimental studies of the effectiveness of reducing the level of the magnetic field in two-storey cottage of the old building of a power transmission line with a horizontal arrangement of wires by means of active shielding with single compensation winding. Methodology Spatial location coordinates of the compensating winding and the current in the shielding winding were determined during the design of systems of active screening based on solution of the vector game, in whith the vector payoffs is calculated based on Biot-Savart's law. The solution of this vector game calculated based on algorithms of multi-swarm multi-agent optimization. Results The results of theoretical and experimental studies of the effectiveness of reducing the level of the magnetic field in two-storey cottage of the old building of a power transmission line with a horizontal arrangement of wires by means of active shielding with single compensation winding are presented. Originality. For the first time, the theoretical and experimental studies of the effectiveness of reducing the level of the magnetic field in two-storey cottage of the old building of a power transmission line with a horizontal arrangement of wires by means of active shielding with single compensation winding are considered. Practical value. From the point of view of the practical implementation it is shown the possibility to reduce the level of magnetic field in two-storey cottage of the old building from power transmission line with a horizontal arrangement of wires by means of active shielding with single compensation winding to the sanitary standards of Ukraine.Документ Comparison of the effectiveness of thriple-loop and double-loop systems of active shielding of a magnetic field in a multi-storey old buildings(Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.The issues of comparing the effectiveness of reducing the level of the magnetic field in a five-storey old buildings generated by a single-circuit overhead power transmission lines with a triangular suspension of wires using a thriple-loop and double-loop systems of active screening, which respectively contain three or two compensating windings are considered. Methodology. Spatial location coordinates of the compensating windings and the currents in the shielding windings were determined during the design of systems of active screening based on solution of the maximin vector optimization problem, in whith the vector of objective function is calculated based on Biot-Savart's law. The solution of this problem is calculated based on algorithms of multi-swarm multi-agent optimization. Results. The results of theoretical and experimental comparing the effectiveness of reducing the level of the magnetic field in a five-storey old generated by a single-circuit overhead power transmission lines with a triangular suspension of wires using a thriple-loop and double-loop systems of active screening, which respectively contain three or two compensating windings are presented. Originality. For the first time, the comparison the effectiveness of reducing the level of the magnetic field in a five-storey old using a thriple-loop and double-loop systems of active screening are considered. Practical value. From the point of view of the practical implementation it is shown the possibility to reduce the level of magnetic field induction in a five-storey old buildings to the sanitary standards of Ukraine for real overhead power transmission lines currents with the help of a synthesized double-loop systems of active screening. A double-loop active screening system is simpler in comparison with a thriple-loop active screening system when implementing.