Видання НТУ "ХПІ"

Постійне посилання на розділhttps://repository.kpi.kharkov.ua/handle/KhPI-Press/62886

Переглянути

Результати пошуку

Зараз показуємо 1 - 2 з 2
  • Ескіз
    Документ
    Maximum power point tracking improvement using type-2 fuzzy controller for wind system based on the double fed induction generator
    (Національний технічний університет "Харківський політехнічний інститут", 2024) Kaddache, M.; Drid, S.; Khemis, A.; Rahem, D.; Chrifi-Alaoui, L.
    In this paper, to maximize energy transmission in wind power system, various Maximum Power Point Tracking (MPPT) approaches are available. Among these techniques, we have proposed the one based on typical fuzzy logic. Despite the somewhat reduced performance of fuzzy MPPT. For a number of reasons, fuzzy MPPT can replace conventional optimization techniques. In practice, the effectiveness of conventional MPPT methods depends mainly on the accuracy of the information given and the wind speed or knowledge of the aerodynamic properties of the wind system. Novelty. Our new MPPT for monitoring the maximum power point has been proposed. We developed an algorithm to improve control performance and govern the stator’s developed active and reactive power using the typical fuzzy logic 2 and enable robust control of a grid-connected, doubly fed induction generator. Purpose. MPPT which implies the wind turbine’s rotating speed should be modified in real time to capture the most wind energy, is necessary to achieve high efficiency for wind energy conversion, according to the aerodynamic characteristics of the wind turbine. Methods. Developing a mathematical model for a wind energy production system is complex, can be strongly affected by wind variation and is a non-linear problem. Thanks to these characteristics, thus, the Lyapunov technique is combined with a sliding mode control to ensure overall asymptotic stability and robustness with regard to parametric fluctuations in order to accomplish this goal. We contrasted our fuzzy type-2 algorithm’s performance with that of the fuzzy type-1 and Perturbation & Observation (P&O) suggested in the literature. Practical value. The simulation results demonstrate that the control performance is satisfactory when using the fuzzy logic technique. From these results, it can be said for the optimization of energy conversion in wind systems, the fuzzy type-2 technique may offer a workable option. Since it presents a great possibility to avoid problems either technical or economics linked to conventional strategies.
  • Ескіз
    Документ
    Passivity voltage based control of the boost power converter used in photovoltaic system
    (Національний технічний університет "Харківський політехнічний інститут", 2022) Baazouzi, Kamel ; Bensalah, Abed Djebar; Drid, Said; Chrifi-Alaoui, Larbi
    This paper presents a robust nonlinear control of the DC-DC boost converter feeding by a photovoltaic system based on the passivity control. The control law design uses the passivity approach. Novelty. The novelty consists in designing a control law for a photovoltaic system using a passivity approach based on energy shaping and associated with damping injection. Purpose. The purpose consists to develop a tool for design and optimize a control law of the photovoltaic system in order to improve its efficiency under some conditions such as the variations of the temperature, the irradiation and the parameters. Also, the control law design should be simple with a lower overshoot and a shorter settling time. Methods. This work uses the port Hamiltonian mathematical approach with minimization of the energy dissipation in boost converter of the photovoltaic system to illustrate the modification of energy and generate a specify duty cycle applied to the converter. Results. The results with MATLAB/SimPowerToolbox® have proven the robustness against parameter variations and effectiveness of the proposed control. Practical value. The experimental results, carried out using a dSPACE DS1104 system, are presented to show the feasibility and the robustness of the proposed control strategy against parameter variations.