Видання НТУ "ХПІ"
Постійне посилання на розділhttps://repository.kpi.kharkov.ua/handle/KhPI-Press/62886
Переглянути
4 результатів
Результати пошуку
Документ Requirements for cables as categories of construction products and thermal resistance of power cables(Національний технічний університет "Харківський політехнічний інститут", 2024) Bezprozvannych, G. V.; Grynyshyna, M. V.; Moskvitin, Y. S.Introduction. One of the main driving factors of the demand for cable and conductor products is the modern trend of urbanization, which leads to an increase in cities with significantly increased requirements for electrical networks of transportation and distribution of electrical energy. This requires the development of appropriate infrastructure with significant demand for electricity in the commercial, industrial and residential sectors. The construction industry uses a wide range of cables with an appropriate set of electrical and mechanical properties, resistance to the influence of external climatic factors, and, first of all, must meet fire safety requirements. Increasing construction activity is stimulating the market for fire-resistant cables in the construction industry. According to the Construction Products Regulation, power, telecommunication cables, data cables, control and management, fiber optic refer to construction products in the EU member states. These cables are intended for the supply of electrical energy and communication, which are permanently installed in buildings and other engineering structures. Power, telecommunications, data and control cables are considered construction products, and are the only electrical products classified as construction. Over the next 15 years, Eastern Europe is expected to see increased growth in the construction industry, as the end of the war in Ukraine requires nearly $1 trillion in reconstruction. A strategic task in the reconstruction of the country is the use of cable and conductor products with increased operational properties, including in the construction industry. Significant efforts and investments in innovation and certification of cable and conductor products require manufacturers to create construction products of the "Power, control and communication cables" category with a high level of fire safety in accordance with the Euroclassification of cables in terms of reaction to fire depending on the level of safety. Purpose. Analysis of fire safety requirements for cables as a category of construction products and determination of thermal resistance of power cables based on experimental thermal studies of modern electrical insulating compositions. Methodology. The thermal stability of power cables with a voltage of 0,66/1 kV was determined, depending on the design, based on the conducted experimental studies of the thermal stability of electrical insulation materials, between the core filling and the polymer sheath, removed from the cable samples. On the basis of the conducted correlation analysis between thermal resistance and fire load, which are important parameters for confirming the quality and safety of the entire cable, it has been proven that the efficiency of halogen-free compositions to meet fire safety requirements increases with the increase in the cross-section and number of cores in the cable. Practical value. Determining the heat load and fire resistance of cables of various designs and areas of application based on the obtained experimental data on the heat of combustion of polymer cable materials is necessary and justified at the stage of mastering and determining the prospects for the production of cables with modern halogen-free electrical insulation compositions in accordance with fire safety requirements. References 40, figures 6.Документ Стратегія управління старінням кабелів атомних електричних станцій(Національний технічний університет "Харківський політехнічний інститут", 2022) Безпрозванних, Ганна Вікторівна; Москвітін, Євгеній СергійовичУправління старінням кабелів є невід'ємною та обов'язковою вимогою для безперервної безпеки та надійної роботи атомних електричних станцій у зв’язку з пролонгацією їх терміну експлуатації. Дослідження наукової спільноти зосереджено на адаптації електричних неруйнівних методів моніторингу зразків кабелів у лабораторних умовах для визначення стану їх електричної ізоляції. Виконаний аналіз програм управління старінням кабелів АЕС доводить за необхідне нових репрезентативних результатів дослідження кабелів для визначення характеристик із застосуванням спеціальних методів контролю та відповідного обладнання. Акцентовано на стратегії управління старінням кабелів із залученням науковців з фаховим досвідом щодо проведення комплексних діагностичних обстежень з кваліфікованим аналізом отриманих результатів на основі найсучасніших технологій. Представлено ефективні методи, методики та сучасна техніка з результати оцінки технічного стану кабелів АЕС.Документ Ensuring standardized parameters for the transmission of digital signals by twisted pairs at the technological stage of manufacturing cables for industrial operating technologies(Національний технічний університет "Харківський політехнічний інститут", 2023) Bezprozvannych, G. V.; Pushkar, O. A.In production control and control systems, buildings use many simple devices - sensors to detect light, heat, movement, smoke, humidity and pressure, mechanisms for activation and control of switches, closing devices, alarm, etc. - «operating technologies» (OT). Different communication protocols and field tire technologies, such as Modbus for conditioning systems, Bacnet for access control and Lonworks for lighting, have been traditionally used and used for their connection. Network fragmentation leads to the need to use gateways to transform protocols when creating a single automation system, which complicates the implementation of complex control systems for any object. At the same time, information networks are unified, but the Ethernet protocol used in them for operating technologies for various reasons (technological, cost) has not been widespread. Due to its high bandwidth compared to existing field tire networks, industrial Ethernet is significantly capable of increasing flexibility in the implementation of additional functions in OT. Modern industrial Ethernet networks are based on non-shielded and shielded twisted pair category 5e cables. The presence of additional metal screens in the structure of twisted pair causes the increase in electrical resistance of conductors due to the effect of closeness, the electrical capacity, and the ratio of attenuation in the range of transmission of broadband signals. Purpose. Substantiation of the range of settings of technological equipment to ensure standardized values of the extinction coefficient and immunity based on the analysis of the results of measurements in a wide frequency range of electrical parameters of shielded and unshielded cables for industrial operating technologies. Methodology. Experimental studies have been performed for statistically averaged electrical parameters of the transmission of pairs for 10 and 85 samples of 305 m long and shielded cables of category 5e, respectively. It is determined that in the frequency range from 1 to 10 MHz, unshielded cables have less values of the attenuation coefficient. In the range of more than 30 MHz, the shielded cables have smaller values of the attenuation due to the influence of the alumopolymer tape screen. It is established that the coefficient of paired correlation between asymmetries of resistance and capacity of twisted pairs is 0,9735 - for unshielded and 0,9257 - for shielded cables. The impact has been proven to a greater extent asymmetry of resistance the pairs on the increasing noise immunity of cables. The influence noise interference on the deviation of the diameter and electrical capacity of the isolated conductor from the nominal values in the stochastic technological process is analyzed. The strategy of technological process settings to ensure the attenuation and the noise immunity in the high-frequency range is substantiated. Practical value. Multiplicative interference, caused by random changes in the stochastic technological process, can lead to a deviation of diameter 2 times from the nominal value at level of probability at 50 %. The equipment settings of the technological equipment must guarantee the coefficient of variation capacity of the insulated conductor at 0.3 % for high level of noise immunity.Документ Ефективні параметри діелектричної абсорбції полімерної ізоляції з напівпровідними покриттями силових високовольтних кабелів(Національний технічний університет "Харківський політехнічний інститут", 2022) Безпрозванних, Ганна Вікторівна; Гринишина, Маргарита ВолодимирівнаНа підставі послідовно-паралельної нелінійної схеми заміщення напівпровідних покриттів та лінійної електричної полімерної ізоляції у широкому діапазоні частоти визначено ефективні параметри діелектричної абсорбції силових високовольтних кабелів одножильного виконання. За результатами моделювання, з урахуванням дисперсії електрофізичних характеристик напівпровідних покриттів, доведено, що ефективна електрична ємність тришарової композитної ізоляційної системи визначається ємністю полімерної ізоляції. Встановлено характер частотних залежностей та максимальні значення ефективного тангенсу кута діелектричних втрат в залежності від співвідношення між питомою електропровідністю на постійному і змінному струмі та товщиною напівпровідних екранів. Отримані співвідношення є підставою для розроблення практичних рекомендацій щодо обґрунтування товщини та електрофізичних параметрів напівпровідних покриттів для зменшення їх впливу на ефективний тангенс кута діелектричних втрат тришарової композитної електроізоляційної системи силових високовольтних кабелів.