    Enhancing power system security using soft computing and machine learning
    (Національний технічний університет "Харківський політехнічний інститут", 2023) Venkatesh, Peruthambi; Visali, Nagalamadaka
    To guarantee proper operation of the system, the suggested method infers the loss of a single transmission line in order to calculate a contingency rating. Methods. The proposed mathematical model with the machine learning with particle swarm optimization algorithm has been used to observe the stability analysis with and without the unified power flow controller and interline power flow controller, as well as the associated costs. This allows for rapid prediction of the most affected transmission line and the location for compensation. Results. Many contingency conditions, such as the failure of a single transmission line and change in the load, are built into the power system. The single transmission line outage and load fluctuation used to determine the contingency ranking are the primary emphasis of this work. Practical value. In order to set up a safe transmission power system, the suggested stability analysis has been quite helpful.
  • Ескіз
    Документ
    Reactive power optimization in distribution systems considering load levels for economic benefit maximization
    (Національний технічний університет "Харківський політехнічний інститут", 2023) Srinivasan, G.; Mahesh Kumar Reddy, V.; Venkatesh, P.; Parimalasundar, E.
    The need for electrical energy has been increased sharply due to hasty growth in industrials, social and economic improvements. From the previous studies, it has been agreed that almost 13 % of the total power generated is wasted as heat loss at distribution level. It has been extensively recognized that the node voltage profile along the distribution system can be enhanced under steady state power transfer controlled by proper reactive power compensation. Capacitors have been acknowledged as reactive power compensating device in distribution systems to achieve technical and economical benefits. Novelty of this work is the application of Archimedes optimization algorithm for reactive power optimization in distribution systems so as to obtain an improved solution and also a real 94-bus Portuguese network and modified 12-bus network has been taken and validated for three different load levels which are totally new. Purpose of the proposed work is to maximize the economic benefit by reducing the power loss and capacitor purchase cost at three different load conditions subject to satisfaction of equality and inequality constraints. Methods. The economic benefit has been validated using Archimedes optimization algorithm for three load levels considering three distribution systems. Results. The computational outcomes indicated the competence of the proposed methodology in comparison with the previously published works in power loss minimization, bus voltage enhancement and more economical benefit and proved that the proposed methodology performs well compared to other methods in the literature.
  • Ескіз
    Документ
    Investigations on hybrid line stability ranking index with polynomial load modeling for power system security
    (Національний технічний університет "Харківський політехнічний інститут", 2023) Venkatesh, Peruthambi; Visali, Nagalamadaka
    Introduction. In recent years, numerous non-renewable and renewable energies are connected to the grid to meet the demand. Also, transient variation with loads poses the shortcomings for generating units, transmission and distribution networks. In this regard, the study on choice of suitable load modelling is essential to predict the system characteristics. The aspect of the research design is a ZIP load model, which, when combined with contingency criteria and constant-impedance, constant-current, and constant-power loads, produces realistic and long-term load representations. Purpose. The proposed technique, infers the single transmission line outage for obtaining the contingency ranking to ensure the system behavior. Methods. The proposed mathematical model with hybrid line stability ranking index has been used for observing the stability analysis with and without considering unified power flow controller. Results. The power system involves many unpredictable conditions or contingency conditions like single transmission line outage, double transmission line outage, generator outage and load variations. This paper mainly focuses on the single transmission line outage for obtaining the contingency ranking. Practical value. The recommended stability analysis has been very beneficial in establishing a secure transmission power system.