Видання НТУ "ХПІ"
Постійне посилання на розділhttps://repository.kpi.kharkov.ua/handle/KhPI-Press/62886
Переглянути
5 результатів
Результати пошуку
Документ The method for design of electromagnetic hybrid active-passive shielding by overhead power lines magnetic field(Національний технічний університет "Харківський політехнічний інститут", 2024) Kuznetsov, B. I.; Nikitina, Nikitina; Bovdui, I. V.; Chunikhin, K. V.; Kolomiets, V. V.; Kobylianskyi, B. B.Development of the method for designing electromagnetic hybrid active-passive shield, consisting from active and multy-circuit passive parts, which is characterized by increased effectiveness of reducing the industrial frequency magnetic field created by twocircuit overhead power lines in residential buildings. Methodology. The designing problem of electromagnetic hybrid active-passive shield including robust system of active shielding and multy circuit passive shield of initial magnetic field comes down to a solution of the multy-criteria two-player zero-sum antagonistic game. The game payoff vector calculated based on the finite element calculations system COMSOL Muliphysics. The game solution calculated based on the particles multyswarm optimization algorithms. Results. During the design of the electromagnetic hybrid active-passive shield the coordinates of the spatial arrangement of 11 circuits passive shield and the coordinates of the spatial location of one compensation winding, as well as the current and phase in this winding of the active shielding system are calculated. The results of theoretical and experimental studies of hybrid active and multy-circuit passive shield by magnetic field in residential building from two-circuit power transmission line with a «Barrel» type arrangement of wires presented. Originality. For the first time the method for designing hybrid active and multycircuit passive shield, consisting from active and multy-circuit passive parts, which is characterized by increased effectiveness of reducing the magnetic field of industrial frequency created by two-circuit overhead power lines in residential buildings is developed. Practical value. Based on results of calculated study the shielding efficiency of the initial magnetic field what is confirmed by experimental studies determined that shielding factors whith only multy-circuit passive shield is more 1.2 units, whith only active shield is more 4 units and with electromagnetic hybrid active-passive shield is more 6.2 units. It is shown the possibility to reduce the level of magnetic field induction in residential building from two-circuit power transmission line with a «Barrel» type arrangement of wires by means of electromagnetic hybrid active shielding with single compensating winding and multy-circuit passive shielding with 11 circuit passive shield to 0.5 μT level safe for the population.Документ The method for design of combined electromagnetic shield for overhead power lines magnetic field(Національний технічний університет "Харківський політехнічний інститут", 2024) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Chunikhin, K. V.; Kolomiets, V. V.; Kobylianskyi, B. B.Aim. Development of the method of designing a combined electromagnetic shield, consisting of active and passive parts, to improve the effectiveness of reduction of industrial frequency magnetic field created by two-circuit overhead power lines in residential buildings. Methodology. The problem of design of combined electromagnetic shield including robust system of active shielding and electromagnetic passive shield of initial magnetic field solved based on of the multi-criteria two-player antagonistic game. The game payoff vector calculated based on the finite element calculations system COMSOL Muliphysics. The game solution calculated based on the particles multiswarm optimization algorithms. During the design of combined electromagnetic shields spatial location coordinates of shielding winding, the currents and phases in the shielding winding of active shielding, geometric dimensions and thickness of the electromagnetic passive shield are calculated. Results. The results of theoretical and experimental studies of combined electromagnetic passive and active shielding of magnetic field in residential building from power transmission line with a "Barrel" type arrangement of wires presented. Originality. For the first time the method of designing a combined electromagnetic shield, consisting of active and passive parts, for more effective reduction of the magnetic field of industrial frequency created by two-circuit overhead power lines in residential buildings is developed. Practical value. Based on results of calculated and experimental study the shielding efficiency of the initial magnetic field determined that shielding factors whith only electromagnetic passive shield is more 2 units, whith only active shield is more 4 units and with combined electromagnetic passive and active shield is more 10 units. It is shown the possibility to reduce the level of magnetic field induction in residential building from power transmission line with a "Barrel" type arrangement of wires by means of a combined electromagnetic passive and active shielding with single compensating winding to 0.5 μT level safe for the population.Документ Method for design of two-level system of active shielding of power frequency magnetic field based on a quasi-static model(Національний технічний університет "Харківський політехнічний інститут", 2024) Kuznetsov, B. I.; Kutsenko, A. S.; Nikitina, T. B.; Bovdui, I. V.; Kolomiets, V. V.; Kobylianskyi, B. B.Development of method for design a two-level active shielding system for an industrial frequency magnetic field based on a quasistatic model of a magnetic field generated by power line wires and compensating windings of an active shielding system, including coarse open and precise closed control. Methodology. At the first level rough control of the magnetic field in open-loop form is carried out based on a quasi-static model of a magnetic field generated by power line wires and compensating windings of an active shielding system. This design calculated based on the finite element calculations system COMSOL Multiphysics. At the second level, a stabilizing accurate control of the magnetic field is implemented in the form of a dynamic closed system containing, in addition plant, also power amplifiers and measuring devices of the system. This design calculated based on the calculations system MATLAB. Results. The results of theoretical and experimental studies of optimal two-level active shielding system of magnetic field in residential building from power transmission line with a «Barrel» type arrangement of wires by means of active canceling with single compensating winding are presented. Originality. For the first time, the method for design a two-level active shielding system for an power frequency magnetic field based on a quasi-static model of a magnetic field generated by power line wires and compensating windings of an active shielding system, including coarse open and precise closed control is developed. Practical value. It is shown the possibility to reduce the level of magnetic field induction in residential building from power transmission line with a «Barrel» type arrangement of wires by means of active canceling with single compensating winding with initial induction of 3.5 µT to a safe level for the population adopted in Europe with an induction of 0.5 µTДокумент Дослідження впливу параметрів сучасних грозозахисних тросів на величину втрат потужності в них для повітряних ліній електропередавання 330-750 кВ(Національний технічний університет "Харківський політехнічний інститут", 2023) Красножон, Андрій Васильович; Квицинський, Анатолій Олександрович; Буйний, Роман Олександрович; Діхтярук, Ігор Віталійович; Красножон, О. В.Досліджено втрати електроенергії в грозозахисних системах повітряних ліній електропередавання напругою 330-750 kV з грозозахисними тросами, що містять вбудований оптоволоконний кабель. Показано, що ці втрати є значними, залежать від взаємного розташування фаз та тросу, навантаження лінії за струмом та параметрів самого тросу (співвідношення його активного та реактивного опорів) і можуть становити від 1,6 kW/km для ліній 750 kV до сотень W/km для ліній 330 kV. Визначено, що грозозахисні троси з погонним активним опором в діапазоні від 0,32 Ω/km до 1,5 Ω/km будуть мати втрати, близькі до максимальних. Вперше рекомендовано використовувати грозозахисні троси, які містять вбудований оптоволоконний кабель, з погонним активним опором не більше 0,25 Ω/km, що дозволить зменшити втрати потужності та підвищити енергоефективність повітряних ліній електропередавання 330-750 kV.Документ Comparison of the effectiveness of thriple-loop and double-loop systems of active shielding of a magnetic field in a multi-storey old buildings(Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.The issues of comparing the effectiveness of reducing the level of the magnetic field in a five-storey old buildings generated by a single-circuit overhead power transmission lines with a triangular suspension of wires using a thriple-loop and double-loop systems of active screening, which respectively contain three or two compensating windings are considered. Methodology. Spatial location coordinates of the compensating windings and the currents in the shielding windings were determined during the design of systems of active screening based on solution of the maximin vector optimization problem, in whith the vector of objective function is calculated based on Biot-Savart's law. The solution of this problem is calculated based on algorithms of multi-swarm multi-agent optimization. Results. The results of theoretical and experimental comparing the effectiveness of reducing the level of the magnetic field in a five-storey old generated by a single-circuit overhead power transmission lines with a triangular suspension of wires using a thriple-loop and double-loop systems of active screening, which respectively contain three or two compensating windings are presented. Originality. For the first time, the comparison the effectiveness of reducing the level of the magnetic field in a five-storey old using a thriple-loop and double-loop systems of active screening are considered. Practical value. From the point of view of the practical implementation it is shown the possibility to reduce the level of magnetic field induction in a five-storey old buildings to the sanitary standards of Ukraine for real overhead power transmission lines currents with the help of a synthesized double-loop systems of active screening. A double-loop active screening system is simpler in comparison with a thriple-loop active screening system when implementing.