Abstract
The results of speed-up tests of polymeric insulators are presented
at influence of high temperature, humidity and tension, and
loading-time dependences are resulted in view of different concentrations
of acid environment. The laboratory researches in a climatic
chamber are compared with exploitation date. A conclusion about a
dominated factor of high temperature is done due to results of durability
decline process in a shell-bar border.