Abstract

The report examines the development of both aircraft power unit and control system of the secondary power supply for on-board consumers. Compared with the scheme, which includes hydraulic inverter, the scheme with non-constant speed generator, rectifier,inverter and sine filter is enable to increase efficiency with the same dimensions and weight. The structure of the control teqnique was given. Less than 4% THD was achieved by correction of every harmonics.

Description

Citation

Анучин А. С. Выбор рациональной структуры цифровой системы управления источников вторичного стабилизированного питания переменного тока / А. С. Анучин, В. И. Кульманов, Ю. О. Беляков // Вестник Нац. техн. ун-та "ХПИ" : сб. науч. тр. Темат. вып. : Проблемы автоматизированного электропривода. – Харьков : НТУ "ХПИ". – 2013. – № 36 (1009). – С. 234-235.