Документ Thermal Process Integration in the AVDU A12/2 Crude Distillation Unit during Winter Operation(Pleiades Publishing, Ltd., 2009) Tovazhnyanskii, L. L.; Kapustenko, P. A.; Ul’ev, L. M.; Boldyrev, S. A.; Arsen’eva, O. P.; Tarnovskii, M. V.A pinch analysis of the AVDU A12/2 crude distillation unit processing 2 million tons of crude oil per year is made. A pinch retrofit of the recuperative heat-exchange system of the unit is performed. It is shown that the implementation of the proposed project will reduce the arbitrary energy consumption by 60 %, which corresponds to a reduction in specific fuel consumption from 36 to 13 kg per ton of refined oil.