Кафедри
Постійне посилання на розділhttps://repository.kpi.kharkov.ua/handle/KhPI-Press/35393
Переглянути
9 результатів
Результати пошуку
Документ Influence of geometrical parameters of the inductor and armature on the indicators of a linear pulse electromechanical converter of an electrodynamic type(National Technical University "Kharkiv Polytechnic Institute", 2019) Bolyukh, V. F.; Kashanskij, Yu. V.; Schukin, I. S.Purpose. The aim of the paper is to study the influence of geometrical parameters, namely, the number of layers and the cross section of the copper tire of the inductor and the armature coils on the power and speed indicators of a linear pulse electromechanical converter (LPEC) of an electrodynamic type. Methodology. On the basis of the developed chain mathematical model, recurrent relations are obtained for the calculation of interconnected electromagnetic, mechanical and thermal processes of LPEC of an electrodynamic type. The effect of the thickness of a square copper tire and the number of its layers in the inductor and armature coils on the characteristics and characteristics of electrodynamic LPEC is investigated. It is these parameters that determine the number of turns and the axial height of the coils with limited radial dimensions. Results. The influence of the geometrical parameters of the inductor and the armature coils with limited radial dimensions on the electrical and mechanical characteristics of LPEC of an electrodynamic type is established. It has been established that with an increase in the thickness of a rectangular cross-section of copper tire from 1 to 2.5 mm, an increase in the amplitude and pulse of electrodynamic forces (EF) occurs. However, the maximum speed of the armature is the highest at LPEC wound with a 1.5 mm thick tire. The highest efficiency value is demonstrated by LPEC, in which the inductor and armature coils are wound with a 2 mm thick tire. With an increase in the number of layers of the inductor coil tire, the amplitude of the EF decreases significantly, and the magnitude of the EF pulse decreases slightly. As a result, the maximum armature speed, efficiency and temperature rise of the coils are reduced. Originality. It is established that the largest amplitude of the EF is realized in LPEC with the minimum number of layers of tires of the inductor and armature coils. The largest value of the pulse EF occurs when the maximum number of layers of the inductor and the armature. In this case, the largest values of the amplitude and pulse of the EF occur under the condition that the number of tire layers of the inductor and the armature coils are the same. Practical value. It has been established that the greatest efficiency 21.82 % is realized in LPEC, in which the number of tire layers is 2 mm thick with inductor and armature coils are 4. A catapult model for launching an unmanned aerial vehicle was made and tested on the basis of LPEC of an electrodynamic type.Документ Influence of an excitation source on the power indicators of a linear pulse electromechanical converter of induction type(Інститут електродинаміки НАН України, 2021) Bolyukh, V. F.; Shchukin, I. S.The purpose of the article is to evaluate the efficiency of an induction-type linear pulse electromechanical converter (LPEC) when operating in shock-power mode and excitation from an alternating voltage source (AVS) in comparison with excitation from a capacitive energy storage (CES). A mathematical model of an induction-type LPEC has been developed both when excited by a unipolar pulse from a CES and from an AVS using lumped parameters of the windings, which takes into account the interrelated electromagnetic, mechanical and thermal processes. It has been found that when the LPEC is excited from the AVS with a voltage frequency of 50 Hz, the electrodynamic force takes on a periodic decaying character with a significant prevalence of positive components of forces over negative ones. The maximum value of the force is much less, and the value of its impulse is much greater than in the LPEC, excited from the CES. With an increase in the frequency of the AVS voltage from 50 to 150 Hz, the highest value of the current density of the inductor winding decreases, and in the armature winding it increases. The greatest values of force and impulse of force are realized at a voltage frequency of 150 Hz. With an increase in the AVS frequency, the relative indicator of the efficiency of the LPEC increases.Документ Excitation of a pulse electromechanical converter of electrodynamic type from a two-section capacitor energy storage(Інститут електродинаміки НАН України, 2021) Bolyukh, V. F.A mathematical model of a pulsed electromechanical converter (PEC) of electrodynamic type has been developed, in which the solutions of the equations are presented in a recurrent form, which, when numerically implemented, allows taking into account the interrelated electrical, magnetic, mechanical and thermal processes and their nonlinear parameters. While maintaining the total energy of the pulsed source, the influence of the distribution of energy between the two sections of the capacitive energy storage (CES) and the voltage at which the additional section of the CES is connected was established. When operating in an accelerating mode, the largest amplitude of electrodynamic forces (EDF) and maximum speed occur in the basic version of the PEC, which is excited only from the main section of the CES, and the most effective is the PEC with the smallest capacity of the main section of the CES, and its maximum value is 2.61 higher than for the basic version of the PEC. When operating in the shock-power mode, compared with the basic version of the PEC, the amplitude of the EDF decreases. The most effective is the PEC with the smallest capacity of the main section of the CES, and its maximum value is 5.17 higher than that of the basic version of the PEC. Experimental studies of the PEC in the shock-power mode established that the oscillograms of the voltage of the CES and the current of the PEC correspond to the calculated characteristics, and their main indicators are consistent with each other with an accuracy of 5-7%.Публікація Influence of pulse excitation on electromechanical indicators of a linear pulse converter of electrodynamic type(Національний гірничий університет, 2020) Bolyukh, V. F.; Kashanskyi, Yu. V.; Shchukin, I. S.Purpose. Investigation of the effect of pulsed excitation of the electronic circuit-controlled inductor and armature windings, powered with the capacitive energy storage (CES) source, on the speed and power indicators of a linear pulse electrodynamic converter (LPEC). Methodology. On the basis of the developed numerical model, the influence of pulsed excitation — vibrationally damped, halfwave, aperiodic, and aperiodic with recharge, on the characteristics and performance of LPEC is studied. The mathematical model of the LPEC, using the lumped parameters of the stationary winding of the inductor and the movable winding of the armature, takes into account the interconnected electromagnetic, mechanical and thermal processes, presenting their solutions in a recursive form. Findings. It was found that the pulse excitation of the LPEC insignificantly affects the maximum speed, the pulse of electrodynamic forces (EDF) and the temperature rise of the inductor winding. The highest values of the maximum speed and impulse of an EDF arise upon excitation by a vibrationally damped current pulse, while the smallest ones – upon excitation by an aperiodic pulse. The LPEC excitation by an aperiodic current pulse with recharge allows the use of a reduced charge voltage for rechargeable CES. With a decrease in this voltage and with conservation of the energy of the CES, the amplitude of the EDF decreases by 31.5 %, but due to the delay of electromagnetic processes, the pulse of the EDF increases by 3 %, and the efficiency – by 8.2 %. Originality. A comprehensive criterion for the LPEC efficiency was introduced, which takes into account the amplitude of the excitation current, the mass of the windings, the temperature of the inductor winding, the magnitude of the EDF pulse, the efficiency, and the maximum speed for a given reliability coefficient. Using this criterion, we found that in terms of power and speed indicators, the most efficient is a converter excited by an aperiodic current pulse with recharge, and the quality of work is a converter excited by an aperiodic pulse. Practical value. The influence of the width of the copper bus and the corresponding axial heights of the windings of the inductor and the armature on the speed and power performance of the LPEC using vibration-damping, half-wave, aperiodic and aperiodic with recharge current pulses is established.Документ Effect of electric conducting element on indicators of linear pulse electromechanical converter induction type(Інститут електродинаміки НАН України, 2020) Bolyukh, V. F.The purpose of the article is to study the influence of geometric parameters and the location of a coaxially located electrically conductive element (ECE), made in the form of a thin-walled disk, ring or hollow cylinder, on the characteristics and performance of an induction-type linear pulse electromechanical converter (LPEC). A mathematical model has been developed that describes the electromechanical and thermal processes in an induction-type LPEC using the concentrated parameters of active elements. It is shown that the ECE, coaxially mounted near the inductor winding, has a negative effect on the performance of the LPEC. The smallest value of the converter efficiency of 6.1% occurs when ECE is used in the form of a thin copper disk 0.5 mm high, in which the radial dimensions are similar to the sizes of the windings of the inductor and the armature installed at a minimum distance from the inductor. Moreover, the temperature rise of the electrically conductive element is maximum and equal to 51°С. With an increase in the thickness of the ECE and with its removal from the inductor, the efficiency of the LPEC increases, and the excess of the temperature of the ECE decreases. When removing a disk ECE with a height of 1.0 mm at a distance of 10 mm from the inductor, the efficiency of the LPEC is 12.6%, and the excess of the ECE temperature is 6 °C.Документ Axial coil accelerator of plasma ring in the atmospheric pressure air(National Science Center "Kharkov Institute of Physics and Technology", 2019) Korytchenko, K. V.; Bolyukh, V. F.; Rezinkin, O. L.; Burjakovskij, S. G.; Mesenko, O. P.An axial coil accelerator for acceleration of plasma formation having intrinsic magnetic field in the atmosphere is designed. A problem of a round plasma formation in the atmospheric pressure air is solved by electrical wire explosion where an initial form of an exploding wire corresponded to a ring. A vortex current into the created plasma ring is inducted by the coil accelerator to generate intrinsic magnetic field of the plasma formation. This process is synchronized with reduction in the magnetic coupling between the plasma formation and the accelerator coil during the acceleration.Документ Increasing the efficiency of the surface-mounted ultrasonic electromagnetic-acoustic transducer on account of the magnetic field source(Інститут електродинаміки НАН України, 2023) Suchkov, G. M.; Bolyukh, V. F.; Kocherga, A. I.; Mygushchenko, R. P.; Kropachek, O. Yu.Model studies were carried out using the COMSOL Multiphysics package, aimed at ensuring the forming of a permanent magnet magnetic field at a considerable distance to a ferromagnetic product from its pole, which is necessary to create efficient portable ultrasonic electromagnetic-acoustic transducers of thickness gauges and testing and diagnostic devices. It is theoretically shown and experimentally confirmed that for portable measuring ultrasonic devices it is expedient to set the height of the permanent magnet at about 60 mm and the cross section of the magnet pole 50x50 mm2. At the same time, with a gap between the magnet pole and the product of about 30 mm, the value of the normal component of the magnetic field induction near the surface of the object is about 0.3...0.4 T, which is sufficient for thickness gauging or diagnostics of ferromagnetic products using the ultrasonic pitch-and catch method.Документ Comparative analysis of constructive types of combined linear pulmonary electromechanical converters(Симфонія форте, 2018) Bolyukh, V. F.; Kocherga, O. I.Документ Theoretical and experimental study of linear impulse induction type electromechanical converter(Симфонія форте, 2017) Bolyukh, V. F.; Kocherga, O. I.