Кафедри
Постійне посилання на розділhttps://repository.kpi.kharkov.ua/handle/KhPI-Press/35393
Переглянути
5 результатів
Результати пошуку
Документ The method of multi objective synthesis of stochastic robust control by multimass electromechanical systems under non-gausian random external disturbances(Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.Development of the method of multi objective synthesis of stochastic robust control by multimass electromechanical systems to satisfy various requirements for the operation of such systems in various modes under non-gausian random external disturbances. Methodology. The problem of multi objective synthesis of stochastic robust control by multimass electromechanical systems to satisfy various requirements for the operation of such systems in various modes under non-gausian random external disturbances solved based on the choosing of weight matrices in the robust control goal vector.The calculation of the target vector is performed based on the solution of the zero-sum vector antagonistic game. The components of the game payoff vector are variable quality indicators that are applied to the system operation in various modes. The calculation of the components of payoff vector game are performed based on the simulation of the initial system closed by the synthesized stochastic controllers in various operating modes and under various external influences and variations in the parameters of the uncertainty of the initial plant. Results. The results of multi objective synthesis of stochastic robust twomass electromechanical servo systems modes under non-gausian random external disturbances in which differences requirements for the operation of such systems in various modes were satisfied are given. Based on the results of modeling and experimental studies it is established, that with the help of synthesized robust nonlinear controllers, it is possible to improve of quality indicators of two-mass electromechanical servo system in comparison with the system with standard regulators. Originality. For the first time the method of multi objective synthesis of stochastic robust control by multimass electromechanical systems to satisfy various requirements for the operation of multimass systems in various modes is developed. Practical value. From the point of view of the practical implementation the possibility of solving the problem of multi objective synthesis of stochastic robust control systems to satisfy various requirements for the operation of multimass electromechanical systems in various modes is shown.Документ The method of multi objective synthesis of nonlinear robust control by multimass electromechanical systems(Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobilyanskiy, B. B.Development of the method of multi objective synthesis of nonlinear robust control by multimass electromechanical systems to satisfy various requirements for the operation of multi-mass systems in various modes. Methodology. The problem of multi objective synthesis of nonlinear robust control of multimass electromechanical systems is formulated and the possibility of satisfying various requirements for the operation of such systems in various modes based on the concept of functionally multiple membership of the state vector and the solution of the Hamilton-Jacobi-Isaacs equation is shown. A method for choosing weight matrices with the help the vector of purpose of nonlinear robust control is formed by solving a zero-sum vector antagonistic game has been substantiated and developed. Results. The results multi objective synthesis of nonlinear robust two-mass electromechanical servo systems in which differences requirements for the operation of such systems in various modes were satisfied are given. Based on the results of modeling and experimental studies it is established, that with the help of synthesized robust nonlinear controllers, it is possible to improve of quality indicators of two-mass electromechanical servo system in comparison with the system with standard regulators. Originality. For the first time the method of multi objective synthesis of nonlinear robust control by multimass electromechanical systems to satisfy various requirements for the operation of multimass systems in various modes is developed. Practical value. From the point of view of the practical implementation the possibility of solving the problem of multi objective synthesis of nonlinear robust control systems to satisfy various requirements for the operation of multimass electromechanical systems in various modes is shown.Документ Comparison of the effectiveness of thriple-loop and double-loop systems of active shielding of a magnetic field in a multi-storey old buildings(Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskyi, B. B.The issues of comparing the effectiveness of reducing the level of the magnetic field in a five-storey old buildings generated by a single-circuit overhead power transmission lines with a triangular suspension of wires using a thriple-loop and double-loop systems of active screening, which respectively contain three or two compensating windings are considered. Methodology. Spatial location coordinates of the compensating windings and the currents in the shielding windings were determined during the design of systems of active screening based on solution of the maximin vector optimization problem, in whith the vector of objective function is calculated based on Biot-Savart's law. The solution of this problem is calculated based on algorithms of multi-swarm multi-agent optimization. Results. The results of theoretical and experimental comparing the effectiveness of reducing the level of the magnetic field in a five-storey old generated by a single-circuit overhead power transmission lines with a triangular suspension of wires using a thriple-loop and double-loop systems of active screening, which respectively contain three or two compensating windings are presented. Originality. For the first time, the comparison the effectiveness of reducing the level of the magnetic field in a five-storey old using a thriple-loop and double-loop systems of active screening are considered. Practical value. From the point of view of the practical implementation it is shown the possibility to reduce the level of magnetic field induction in a five-storey old buildings to the sanitary standards of Ukraine for real overhead power transmission lines currents with the help of a synthesized double-loop systems of active screening. A double-loop active screening system is simpler in comparison with a thriple-loop active screening system when implementing.Документ The method of limitation of dynamic loads of nonlinear electromechanical systems under state vector robust control(Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobilyanskiy, B. B.Development of the method of limitation of dynamic loads of nonlinear electromechanical systems under state vector robust control. MethodologyLimitation of dynamic loads of nonlinear electromechanical systems is carried out using the minimum selector of choosing the minimum value of the control vector from formed with the help of local controllers and with the vector of maximum control values. Calculation of the gain coefficients of nonlinear robust controllers and observers are based on solutions of the Hamilton–Jacob–Isaacs equations. Results. The results of computer simulation of transitional processes of main roll drives of the rolling mill 950 of the Zaporozhye plant «Dnіprospetsstal» with limitation of dynamic loads are given. Originality. For the first time the method of limitation of dynamic loads of nonlinear electromechanical systems under state vector robust control based on minimum selector and nonlinear robust control of state variables which is needed limitation is developed. Practical value. Examples of transitional processes of main roll drives of the rolling mill 950 of the Zaporozhye plant «Dnіprospetsstal» with limitation of dynamic loads are given.Документ Method of adjustment of three circuit system of active shielding of magnetic field in multi-storey buildings from overhead power lines with wires triangular arrangement(Національний технічний університет "Харківський політехнічний інститут", 2022) Kuznetsov, B. I.; Nikitina, T. B.; Bovdui, I. V.; Voloshko, O. V.; Kolomiets, V. V.; Kobylianskiy, B. B.For the first time the method of adjustment of three circuit system of the active shielding of the magnetic field based on experimentally determined space-time characteristics to increase the shielding factor in a multi-storey building located near a singlecircuit overhead transmission lines with a wires triangular arrangement was developed. Methodology. When synthesizing the laboratory model of system of active shielding the coordinates of spatial arrangement and of three shielding coils, the currents in shielding coils and resulting magnetic flux density value in the shielding space were calculated. The synthesis is based on the multi-criteria game decision, in which the payoff vector is calculated on the basis on quasi-stationary approximation solutions of the Maxwell equations. The game decision is calculated based on the stochastic particles multi swarm optimization algorithms. Results. Computer simulation and experimental research of the space-time characteristics of laboratory model of three circuit system of active shielding of magnetic field, generated by overhead power lines with phase conductors triangle arrangements in multi-storey building are given. The possibility of initial magnetic flux density level reducing to the sanitary standards level is shown. Originality. For the first time the synthesis and adjustment of laboratory model of three circuit system of active shielding of magnetic field based on experimentally determined spacetime characteristics to increase the shielding factor in a multi-storey building located near a single-circuit overhead transmission lines with a wires triangular arrangement carried out. Practical value. Practical recommendations from the point of view of the implementation of developed method of adjustment of the three circuit system of the active shielding of the magnetic field based on experimentally determined space-time characteristics in a multi-storey building located near a single-circuit overhead transmission lines with a triangular arrangement of wires are given.