Анализ срока окупаемости модернизированной насосной установки при использовании асинхронных двигателей повышенных классов энергоэффективности
Loading...
Date
item.page.orcid
item.page.thesis.degree.name
item.page.thesis.degree.level
item.page.thesis.degree.discipline
item.page.thesis.degree.department
item.page.thesis.degree.grantor
item.page.thesis.degree.advisor
item.page.thesis.degree.committeeMember
Journal Title
Journal ISSN
Volume Title
Publisher
Національний технічний університет "Харківський політехнічний інститут"
Abstract
It has been demonstrated, than in case of replacement of an induction motor of energy efficiency class IE2 due to plannedretrofit, payback period for an IE4 induction motor is 2.18 years, energy savings within a calculated 20-year operating period are 268MW·h, which makes €41110 in money terms. Under the same conditions, the replacement of an induction motor of energy efficiency class IE2 with an induction motor of energy efficiency class IE3 will allow to save 88 MW·h within a calculated operating period, which, expressed in monetary terms, is €13500 and the payback period is 5.11 years. Thus, the article proves that despite a higher initial price, the choice of an induction motor of energy efficiency class IE4 tends to be more economically advantageous.
Description
Keywords
Citation
Анализ срока окупаемости модернизированной насосной установки при использовании асинхронных двигателей повышенных классов энергоэффективности / В. В. Гоман [и др.] // Електротехніка і Електромеханіка = Electrical engineering & Electromechanics. – 2021. – № 1. – С. 15-19.