Анализ энергоемкости процесса первичной перегонки нефти на установке ЭЛОУ АВТ-3
Loading...
Date
item.page.orcid
DOI
item.page.thesis.degree.name
item.page.thesis.degree.level
item.page.thesis.degree.discipline
item.page.thesis.degree.department
item.page.thesis.degree.grantor
item.page.thesis.degree.advisor
item.page.thesis.degree.committeeMember
Journal Title
Journal ISSN
Volume Title
Publisher
НТУ "ХПИ"
Abstract
In this work we analyze the energy efficiency of the primary process oil re-races at ELOU ABT-3, grid diagram determined heat transfer communication between process streams, and counted for the existing process heat recovery capacity, which was 54 MW. Composite curve revealed shortcomings of the existing heat exchange systems, which lead to an increase in power consumption. The analysis of energy efficiency of the primary distillation process ELOU AVT-3 revealed significant weaknesses in the existing heat exchange systems. This work will form the basis for the development of a new system of heat exchange of the test process, and subsequent modernization of the entire plant.
Description
Citation