Measurement uncertainty evaluation by kurtosis method at calibration of a household water meter
dc.contributor.author | Zakharov, Igor | |
dc.contributor.author | Serhiienko, Maryna | |
dc.contributor.author | Chunikhina, Tetiana | |
dc.date.accessioned | 2024-06-17T10:41:53Z | |
dc.date.available | 2024-06-17T10:41:53Z | |
dc.date.issued | 2020 | |
dc.description.abstract | The investigation of measurement uncertainty evaluation at water meter calibration was considered. The peculiarities of this problem is non-linear measurement model and the significant uncertainty, related with the poor repeatability at the small number of the measurements, which makes it difficult to expanded measurement uncertainty evaluate based on the Bayesian approach. The paper checks the influence of the nonlinearity of the model equation on the accuracy of evaluation the numerical value and the standard uncertainty of the measurand. The application of the kurtosis method in the evaluation of the expanded uncertainty of type B and the application of the law of propagation of the expanded uncertainty in the evaluation of the expanded uncertainty of the measurand are described. The obtained values of the expanded uncertainty are very close to the one obtained from Monte Carlo method. | |
dc.identifier.citation | Zakharov I. Measurement uncertainty evaluation by kurtosis method at calibration of a household water meter [Electronic resource] / Igor Zakharov, Maryna Serhiienko, Tetiana Chunikhina // Metrology and metrology assurance : proc. of the 30th Intern. Sci. Symposium, September 7-11, 2020. – Electronic text data. – Sozopol, 2020. – 4 p. – Access mode: https://metrology-bg.org/fulltextpapers/Proceedings_MMO_2020.pdf, free (date of application 17.06.2024.). | |
dc.identifier.orcid | https://orcid.org/0000-0002-1386-6706 | |
dc.identifier.uri | https://repository.kpi.kharkov.ua/handle/KhPI-Press/78425 | |
dc.language.iso | en | |
dc.subject | household water meter | |
dc.subject | calibration | |
dc.subject | uncertainty of the measurements | |
dc.subject | kurtosis method | |
dc.subject | low of the distribution of the expanded uncertainty | |
dc.title | Measurement uncertainty evaluation by kurtosis method at calibration of a household water meter | |
dc.type | Article |
Файли
Контейнер файлів
1 - 1 з 1
- Назва:
- Zakharov_Measurement_2020.pdf
- Розмір:
- 415.25 KB
- Формат:
- Adobe Portable Document Format
Ліцензійна угода
1 - 1 з 1
Ескіз недоступний
- Назва:
- license.txt
- Розмір:
- 11.25 KB
- Формат:
- Item-specific license agreed upon to submission
- Опис: