Increasing the resolving power of determining the point gamma-radiation source direction in the precision method

dc.contributor.authorGrigoryev, A. N.en
dc.contributor.authorBilyk, Z. V.en
dc.contributor.authorLitvinov, Yu. V.en
dc.contributor.authorPolyansky, N. E.en
dc.contributor.authorSakun, A. V.en
dc.contributor.authorMarushchenko, V. V.en
dc.contributor.authorCherniavskyi, I. Yu.en
dc.contributor.authorVoronkin, E. F.en
dc.contributor.authorPetrukhin, S. Yu.en
dc.contributor.authorKasian, S. V.en
dc.date.accessioned2018-06-14T11:42:33Z
dc.date.available2018-06-14T11:42:33Z
dc.date.issued2017
dc.description.abstractExperiments have demonstrated the possibility of increasing the resolving power of determining the point gamma-radiation source direction in the precision method. The work involved reducing the step of the angle of rotation of an asymmetric absorber and shifting the detector relative to the maximum-minimum absorber thickness boundary. The 137Cs gamma-radiation source direction was determined within the angles of the maximum and minimum thickness boundaries of the asymmetric absorber. The detector position was investigated for the maximum thickness of the asymmetric absorber on the boundary between the maximum and minimum thickness, and for the minimum thickness. The optimal position of the detector was found for the asymmetric absorber boundary, enabling to determine the maximum count rate in the gamma source direction. A specific position of the detector enables observing an increasing gamma radiation scattering over the copperlead surface. The experiment used absorbers with spectrometric telluride-cadmium detectors. Information from the detectors was output to four multichannel gamma-radiation impulse analysers, which operated simultaneously in the spectrometer mode.en
dc.identifier.citationIncreasing the resolving power of determining the point gamma-radiation source direction in the precision method / A. N. Grigoryev [et al.] // Functional Materials. – 2017. – Vol. 24, № 4. – P. 682-686.en
dc.identifier.orcidhttps://orcid.org/0000-0002-2785-0617
dc.identifier.urihttps://repository.kpi.kharkov.ua/handle/KhPI-Press/36713
dc.language.isoen
dc.publisherSTC "Institute for Single Crystals"en
dc.subjectprecision methoden
dc.subjectdetermining the directionen
dc.subjectdetector behind an absorberen
dc.subjectgamma-radiation sourceen
dc.subjectasymmetric absorberen
dc.subjectgamma-radiation scatteringen
dc.titleIncreasing the resolving power of determining the point gamma-radiation source direction in the precision methoden
dc.title.alternativeЗбільшення точності визначення напрямку на точкове гамма-джерело у прецезійному методі та оптимальне розташування детектору в асиметричному поглиначіuk
dc.typeArticleen

Файли

Контейнер файлів
Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
FM_2017_24_4_Grigoryev_Increasing.pdf
Розмір:
1.32 MB
Формат:
Adobe Portable Document Format
Опис:
Ліцензійна угода
Зараз показуємо 1 - 1 з 1
Ескіз недоступний
Назва:
license.txt
Розмір:
11.25 KB
Формат:
Item-specific license agreed upon to submission
Опис: