Компенсированная асинхронная машина с короткозамкнутым ротором

Loading...
Thumbnail Image

Date

ORCID

DOI

item.page.thesis.degree.name

item.page.thesis.degree.level

item.page.thesis.degree.discipline

item.page.thesis.degree.department

item.page.thesis.degree.grantor

item.page.thesis.degree.advisor

item.page.thesis.degree.committeeMember

Journal Title

Journal ISSN

Volume Title

Publisher

НТУ "ХПИ"

Abstract

В работе рассмотрено подключение САФ параллельно АМ для улучшения пусковых характеристик и уменьшения потерь энергии.
The article considers a compensated asynchronous machine that consists of a power active filter and an asynchronous machine switched in parallel. The starting system of the asynchronous machine is set at the nominal voltage of 380 V and power of 75 kW. An equivalent circuit of the system is given, time diagrams of voltage and currents in the system are built for starting of the asynchronous machine with and without the power active filter.

Description

Citation

Жемеров Г. Г. Компенсированная асинхронная машина с короткозамкнутым ротором / Г. Г. Жемеров, В. Ю. Колесник // Электротехника и Электромеханика = Electrical engineering & Electromechanics. – 2009. – № 3. – С. 20-24.