Measuring the amplitude-time characteristics of a pulsed high-intensity gamma radiation acceleratorVarian Clinac 600C aCdTe detector

dc.contributor.authorGrigoryev, A. N.en
dc.contributor.authorBilyk, Z. V.en
dc.contributor.authorLitvinov, Yu. V.en
dc.contributor.authorCherniavskiy, I. Yu.en
dc.contributor.authorPolyansky, N. E.en
dc.contributor.authorSnarenky, V. P.en
dc.contributor.authorSamofalov, I. A.en
dc.contributor.authorVoronkin, E. F.en
dc.contributor.authorSosnutska, O. O.en
dc.contributor.authorPetrukhin, S. Yu.en
dc.contributor.authorSuchkov, G. M.en
dc.contributor.authorBilyk, N. G.en
dc.contributor.authorIndykov, S. N.en
dc.contributor.authorMatykin, V. B.en
dc.contributor.authorPysariev, S. A.en
dc.contributor.authorMatykin, O. V.en
dc.contributor.authorMenshov, S. N.en
dc.date.accessioned2023-02-17T15:04:12Z
dc.date.available2023-02-17T15:04:12Z
dc.date.issued2019
dc.description.abstractMeasurements of the amplitude-time characteristics of a high-intensity pulsed gamma radiation accelerator Varian Clinac 600C with photon energy from 1 to 6 MeV on the equipment using a CdTe detector in both current and pulse modes have been carried out. It is shown that the operation of the CdTe detector in the current mode allows one to control the frequency of the accelerator pulses, and the operation of the CdTe detector in the pulse mode allows for determining the dose in each pulse with an error of 0.06 %. Monitoring the operation of the accelerator Varian Clinac 600 C shows that the pulses come in batches; within the batch, the pulse repetition period corresponds to a specified frequency at the accelerator, while the repetition period of the batches differs from the specified frequency. Dose control in the pulses showed its 5 % excess over the average value during the first 2.5 s of the accelerator operation, whereas during the last 2 s, the dose reduction by 1.8 % was observed.en
dc.identifier.citationMeasuring the amplitude-time characteristics of a pulsed high-intensity gamma radiation accelerator Varian Clinac 600C aCdTe detector / A. N. Grigoryev [et al.] // Functional materials. – 2019. – Vol. 26, No 2. – P. 424-428.en
dc.identifier.doidoi.org/10.15407/fm26.02.424
dc.identifier.orcidhttps://orcid.org/0000-0002-2785-0617
dc.identifier.orcidhttps://orcid.org/0000-0002-1805-0466
dc.identifier.urihttps://repository.kpi.kharkov.ua/handle/KhPI-Press/62499
dc.language.isoen
dc.publisherSTC "Institute for Single Crystals"en
dc.subjectlinear acceleratoren
dc.subjectpulsed gamma radiationen
dc.subjecttelluride cadmium detectoren
dc.subjectpulse frequencyen
dc.titleMeasuring the amplitude-time characteristics of a pulsed high-intensity gamma radiation acceleratorVarian Clinac 600C aCdTe detectoren
dc.title.alternativeВимірювання амплітудно-часових характеристик імпульсного високоінтенсивного гамма-випромінювання прискорювача Varian Clinac 600C дитектором aCdTeuk
dc.typeArticleen

Файли

Контейнер файлів

Зараз показуємо 1 - 1 з 1
Ескіз
Назва:
FM_2019_26_2_Grigoryev_Measuring_the_amplitude.pdf
Розмір:
482.5 KB
Формат:
Adobe Portable Document Format
Опис:

Ліцензійна угода

Зараз показуємо 1 - 1 з 1
Ескіз недоступний
Назва:
license.txt
Розмір:
11.25 KB
Формат:
Item-specific license agreed upon to submission
Опис: