    Allocation of steady-state areas of total electrical load schedules of 10/0.4 kV transformer substations located in residential areas
    (Національний технічний університет "Харківський політехнічний інститут", 2021) Dovgalyuk, Oksana; Shcherbak, Iryna; Kovalova, Yuliia; Korobka, Volodymyr
    Improving the efficiency of regulating the parameters of distribution network modes is an actual task for the energy sector, requiring a detailed analysis of the nature of the total electrical load graphs of 10/0.4 kV transformer substations. The complexity of the problem in consideration is due to the fact that the load variation of transformer substations 10/0.4 kV in residential areas occurs randomly, due to the significant number, wide range and probabilistic nature of the operating modes ofconnected consumers, and the lack of deterministic links between consumers of electricity. The investigated function of total load of transformer substations 10/0.4 kV on a daily interval is non-stationary, in this connection there was a necessity of allocation of stationarity areas for adjusting the process of regulation of parameters of electrical network modes. In order to solve this problem, total load graphs for 10/0.4 kV transformer substations located in a residential area were constructed based on experimental measurements of active and reactive loads. The use of these dependencies made it possible to analyse the distribution law for the active and reactive power of the total load of 10/0.4 kV transformer substations, which change in time is stochastic characterised. The use of probabilistic-statistical modelling was justified to reliably describe the load variation process of 10/0.4 kV transformer substations. The hypothesis of a normal law distribution of the functions under consideration was confirmed and parametric tests were performed. Fisher's F-criterion was used to confirm the hypothesis of variance constancy, and Student's t-criterion was used to confirm the hypothesis of mathematical expectation constancy. Using the fact of constancy of dispersions and expectations of investigated mode parameters, autocorrelation coefficients of investigated random functions were determined and autocorrelation function graphs were plotted. In order to approximate the functions under investigation, the autocorrelation function coefficients were determined using the least-squares method, and an analysis of the attenuation of the autocorrelation function was carried out. The calculations carried out have highlighted the areas of stationarity on the total load curves of the 10/0.4 kV transformer substations. These stationarity plots can be used for further modelling of load graphs and the formation of control actions to adjust the load of consumer regulators in order to equalise the overall electrical load graph, as well as for voltage regulation facilities, which will contribute to the required modes of operation of the electricity distribution networks.
  • Ескіз
    Документ
    Synthesis of fast-operating devices for digital signal processing based on the number­theoretic transforms
    (ПП "Технологічний центр", 2020) Ivashko, A. V.; Liberg, I. G.; Lunin, D. A.
    The selection of special-form moduli and their corresponding primitive roots have been proposed, which provide for a simplified structure of arithmetic devices using number-theoretic transforms. A method for determining moduli has been developed that ensures a minimum number of arithmetic operations when performing the modulo addition and multiplication operations. The structures of special-form modulo adders have been developed and modeled, which make it possible to perform the addition operation as quickly as possible. The modulo adders for the Fermat, Mersenne, and Golomb numbers have been synthesized and tested, which could be used in the arithmetic units of high-speed correlators and filters. Real-time correlation and convolution calculation become a rather time-consuming task in the case of long input sequences. To solve this task, it is advisable to apply the so-called fast algorithms. However, this requires the high-performance calculators of convolution and correlation, which often exceed the capabilities of modern computer equipment, Therefore, the proposed procedure for determining the modulus, as well as the designed structural circuits for special-form modulo adders, make it possible to accelerate the computation of correlations and convolutions using number-theoretic transforms. Since the operation of modulo multiplication is performed using the addition and shift operations, the complexity of calculating the number-theoretic transformations largely depends on the number of unities in the binary representation of the degrees of the primitive root. The operation of multiplication is typically reduced to the multiple addition of numbers, which is why the complexity and speed performance of arithmetic devices for numeric-theoretic transformations is determined by the characteristics of the modulo adders. The proposed method for designing computing moduli for the digital devices that calculate correlation and convolution, based on rapid theoretical-numerical transformations, provides the simplified hardware and software implementation of these structures, resulting in high-speed processing of signals and images.
  • Ескіз
    Документ
    Analysis of fractal noise indicators in measuring systems of technical objects
    (Technical University of Sofia, 2018) Davydov, Viacheslav; Zmiivska, Vitalina; Shypova, Тetiana; Lysytsia, Dmytro
    The indicators and characteristics of the estimation of the noise fractality and interference in systems for measuring the characteristics and condition of technical objects are considered. A reasoned choice of indicators used in prospect for the implementation of the fractality estimation method is carried out.
  • Ескіз
    Документ
    Підвищення точності розрахунку ординат АКФ сигналу розсіяння
    (Національний технічний університет "Харківський політехнічний інститут", 2018) Пуляєв, Валерій Олександрович; Ємельянов, Леонід Якович; Рогожкін, Євген Васильович
    Наведено результат моделювання двох складових автокореляційної функції (АКФ), які відображають статистичні характеристики некогерентного розсіяння, що розраховуються за допомогою основного (косинусного) та ортогонального (синусного) каналів системи кореляційної обробки радара. Продемонстровано алгоритм обчислень АКФ, коли залучається апаратура, де в наявності є два паралельно працюючих ортогональних канали зі своїми незалежними підсилювальними елементами. Показано, що є різні варіанти синхронізації паралельно працюючих ортогональних каналів. В першому з них вхідний сигнал в одному із каналів затримується на чверть періоду проміжної частоти, а в іншому – використовуються різні серії тактування АЦП. В цих серіях положення імпульсів відрізняється, а саме – вони затримані по відношенню один до одного на чверть періоду сигналу на проміжній частоті. Запропоновано зменшити похибки, які виникають в результаті неідентичності технічних характеристик цих двох квадратурних каналів обробки сигналу. Розглянуто нову структурну схему багатоканального корелятора, який одночасно розраховує як косинусну, так і синусну складові автокореляційної функції сигналу розсіяння, причому сигнал до нього надходить тільки через один канал приймача і один АЦП. Також запропоновано збільшити частоту перетворення сигналу в цифрову форму, щоб досягти значно більшу щільність розташування ординат автокореляційної функції вздовж шкали затримок. Як наслідок, результати розрахунку параметрів іоносферної плазми, що визначаються по формі АКФ, будуть мати ще й підвищену статистичну точність обчислень. Для запропонованого варіанту отримання квадратурних складових АКФ запропоновано модифікований вираз для розрахунку значень радіальної швидкості руху іоносферної плазми.
  • Ескіз
    Документ
    Багатоканальний кореляційний пристрій радара некогерентного розсіяння
    (НТУ "ХПІ", 2017) Пуляєв, Валерій Олександрович; Рогожкін, Євген Васильович
    Розглянуто приклад модернізації корелятора радара некогерентного розсіяння, працюючого в реальному часі, в структуру якого вводяться додаткові кореляційні канали та елементи зв'язку між ними. Це дозволяє отримувати висотний розподіл автокореляційних функцій сигналу розсіяння у вигляді основних і дзеркальних складових. Як результат – вздовж напрямку зондування на кожній ділянці без погіршення висотного розрізнення підвищується статистична точність розрахунку характеристик цього сигналу. Також додатково враховуються особливості висотного профілю сигналу розсіяння.